The standard 'environment' for Modbus protocol is RS485/422/232. The typical structure of an automation system that uses Modbus as its basic protocol is shown below. The field level is the level of interaction between sensors and controllers or sensors and the server. The middle level is the level of controllers - devices that collect data and control the technological process. Modbus is a common protocol used in automation systems at the middle and lower (field) levels.
CMD MODBUS POLL SOFTWARE
In this article, we'll cover the key features of the existing software and hardware solutions for testing and debugging devices and networks based on Modbus protocol. All this ensures the growth of Modbus popularity among amateurs and professionals. The development of such projects as Arduino and Raspberry Pi has significantly increased interest in tasks related to robotics and automation. The protocol serves for connecting equipment of various types to a home computer as well. Without such a tool, you're doing blind-debugging.Modbus is a communication protocol commonly used in industrial automation systems, smart home systems, automated networks of small objects (warehouses, greenhouses, etc). As I stated in my comment, I recommend using a logic analyzer to see what's going on on the wire.
CMD MODBUS POLL SERIAL
If you still get timeouts with registeraddress = 45, your Python runtime may have some problems accessing the serial port. A request to access an unaligned data (with a wrong register value) can be simply rejected by the firmware. Maybe a request to access the temperature register actually triggers some measurement function and then returns a value. But we can't know how the device works internally. So when using this library, you need to use registeraddress = 45 for accessing the temperature, not 46 or 40046.īut why won't 46 work? Normally, one would expect it to grab data starting from the next register and print some garbage, but not timeout. I think it's safe to assume that both use the same addressing which starts from 1, as the command-line tool has no problems accessing the value.īut MinimalModbus API clearly mentions that its register start address is 0. But its documentation mentions that the default value for -r parameter is 1. Similarly, the mbpoll command-line utility (not the one with GUI) isn't very clear about the start address.
CMD MODBUS POLL MANUAL
The device manual isn't clear about the register start address, but the first register it mentions has the address of 1. Temperature = instrument.read_long(registeraddress=9001, functioncode=3,īyteorder=0) # Registernumber, number of decimals
CMD MODBUS POLL CODE
I apologies for my armature code but the solution that works for me is the below - import minimalmodbus

As semi-alluded to in other suggestions the device I am connecting to has a 'sleep' period or the like and needs to be polled once, unsuccessfully, before successfully returning values for any subsequent polls. Just updating with the solution if anyone happens to stumble upon this and has the same problem. I have also tried depth = instrument.read_long(x, x) with different values I am not married to minimal modbus - I am happy to use any tool to get this done Register is 40046, so I understand this to be register 45 of the holding registers? How do I translate this to minimalmodbus? I am able to read a register using Modbus Poll. I have tried to incorporate minimal modbus structure but to no avail.
CMD MODBUS POLL PC
Temperature = instrument.read_float(registeraddress=45, functioncode=4, number_of_registers=2, byteorder=0) # Registernumber, number of decimalsĭevice is a Level Troll 400 Connected to PC via manufactures cable #nstrument.clear_buffers_before_each_transaction = True Temperature = instrument.read_float(registeraddress=40046, functioncode=3, number_of_registers=2, byteorder=0) # Registernumber, number of decimals Instrument.clear_buffers_before_each_transaction = True Instrument.mode = minimalmodbus.MODE_RTU # rtu or ascii mode Instrument.address = 1 # this is the slave address number Instrument = minimalmodbus.Instrument('COM5', 1) # port name, slave address (in decimal) My code is as follows - import minimalmodbus (Address different as running on Pi not PC) Register is readable in mbpoll using - mbpoll -B -m RTU -t 4:float -a 1 -b 19200 -r 46 -c 2 /dev/ttyUSB0 I am getting no response from the instrument.

I have confirmed the COM port, Baud rate and other communication settings and I can use the devices application to read the value (it is a water level logger).

I am trying to use Python (P圜harm) to read a register on a modbus device.